Client
Private homeowners
Location
Stretford, Greater Manchester
Technologies used
Air source heat pump, solar PV, 13.5 kWh battery storage, underfloor heating, radiators and comfort cooling.
Key outcome
Approximately 90% reduction in heating demand, with near-zero energy bills.
Featured on Channel 4's Guy Martin's House Without Bills, Park Haus demonstrates what's possible when fabric-first renovation meets carefully designed renewable energy systems.
Project Overview
A whole-house approach to energy efficiency
Park Haus was an ambitious deep retrofit of a 1930s semi-detached home in Stretford, Greater Manchester, featured on Channel 4’s Guy Martin’s House Without Bills in February 2026.
Led by Passivhaus designers Progress in Practice and main contractor Myzsa Group, the project aimed to transform an ordinary property into a comfortable, energy-efficient forever home.
PCL Net Zero was appointed to design and install the renewable heating and energy systems, integrating heat pump technology, solar PV, battery storage and heating distribution as part of the wider retrofit.
The Property
A 1930s home reimagined for modern living
Originally a typical semi-detached property with poor insulation and single glazing, Park Haus underwent a comprehensive renovation following the Passivhaus EnerPHit approach.
Improvements included internal and external wall insulation, upgraded floor and loft insulation, triple glazing and enhanced airtightness. A modest rear extension and reconfigured layout also introduced accessible living spaces, including a ground-floor shower room and level access to the garden.
These improvements significantly reduced heat loss, creating the conditions for a smaller, more efficient renewable heating system.
90% less heating demand. A home designed for near-zero energy bills.
The challenge
Making a 1930s home exceptionally energy efficient
The challenge was to transform a conventional 1930s property into a home capable of operating with minimal energy consumption.
With high heating demand and substantial heat loss, the existing building first required significant improvements to its thermal performance.
PCL Net Zero then needed to design a renewable heating and energy system appropriately sized for the upgraded property, ensuring efficient operation, year-round comfort and minimal reliance on imported electricity.
The solution
Integrated renewable technology, designed to work together
PCL Net Zero designed and installed a complete renewable energy system centred around a Vaillant air source heat pump, providing efficient heating and hot water.
Underfloor heating and radiators were incorporated to distribute heat throughout the property, while comfort cooling supports indoor temperatures during warmer months.
Solar PV panels were paired with a 13.5 kWh battery storage system, allowing electricity generated during the day to be stored for use in the evening and overnight.
Combined with the property’s extensive insulation, triple glazing and improved airtightness, the integrated system was designed to deliver maximum efficiency with minimal energy demand.
Installation
Expert installation, featured on Channel 4
PCL Net Zero’s engineers installed the air source heat pump, solar PV, battery storage, underfloor heating, radiators and comfort cooling, working alongside the wider project team.
The installation was filmed for Channel 4’s Guy Martin’s House Without Bills, showcasing the practical expertise required to deliver a high-performance renewable energy system.
Guy Martin described the engineers as “brilliant tradesmen and very confidence inspiring”, recognising the importance of skilled installation in achieving the project’s ambitions.
The result
A comfortable home with dramatically reduced energy demand
The completed retrofit achieved an approximately 90% reduction in heating demand, with modelled demand of around 25 kWh/m² per year.
With significantly less energy required for heating, the combination of a small air source heat pump, solar PV and battery storage helps minimise electricity imported from the grid and supports near-zero energy bills.
Park Haus is now a comfortable, accessible and highly efficient forever home, designed to perform for decades to come.
Sustainability and carbon impact
A practical example of low-carbon home renovation
Park Haus demonstrates how existing UK housing can be transformed through fabric-first improvements and integrated renewable technologies.
The wider renovation incorporated natural and low-VOC materials, reclaimed building elements, high-performance insulation and triple glazing, helping reduce both operational energy demand and the environmental impact of construction.
PCL Net Zero’s installation of an R290 air source heat pump, solar PV and battery storage reduces reliance on fossil fuel heating and imported electricity.
Featured on national television, the project demonstrates the potential of deep retrofit to significantly reduce household energy consumption and associated carbon emissions.